introduction
MONADINOS-600 : Serial to Ethernet Convertor
features
technical details
Specificcation
Protocol | TCP, UDDP, IP, ARP, ICCMP, IGMP, MAAC, DHCP, PPPoE, DNS |
---|---|
Network Interface | 10/100 Base-T Etheernet (Auto ddetection) |
Serial Port | 2 UART((RS232, 3.3VV LVTTL) |
CPU | 8051 compatible |
Serial line format | 8-N-1, 88-O-1, 8-E-1,, 7-O-1, 7-E-1 |
Serial flow control | None, XON/XOFF, CTS/RTS |
Serial signal | TXD, RXD, RTS, CTS, GND |
Software | Remote Download and Configuration |
Serial Transmission Speed | 1200bpss ~ 230Kbps |
Temperature | -20’C ~ 70’C (Operaating), -40~~85’C (Storagge) |
Humidity | 10~90% |
Power | 5V, 500mA(MAX) |
Connector type | D-Sub 9 |
Size | 120mm(W) x 80mm(D) x 40mm(H) |
how to use
Original : http://www.monadinc.co.kr/products/INOS-600.html
System Overview
This device enables remote measurement and connects to existing equipment with an RS-232 serial interface to remotely manage the device through a network based on Ethernet and TCP / IP.
In other words, the INOS-600 is a protocol converter that transfers data to and from a serial device in TCP / IP data types and vice versa.