Web Relay Controller with 20 or 30 Amp Relays & Web Page Interface

Industrial Quality Web Relay Controllers - Available with 1, 2, 4, or 8 On-Board Relays - Available with 20-Amp SPDT or 30-Amp SPST Relays - ProXR Command Set Used by Industry for Many Years - Supports Windows, Mac, Linux, and Android - Supports LabVIEW and Visual Studio - TCP Socket or Virtual Serial Port Communications - Use NCD Base Station Software to Learn Commands
introduction

Web Relay Controller Boards from NCD

Our Web Relay Boards make it easy for you to control relays and monitor inputs using any web browser or software. A Web Relay Board allows you turn relays on or off, create macros to send multiple commands, monitor inputs, and write your own software to do any of these things and more with your own software. This Web Relay Controller is a ProXR Lite series controller which is a widely adopted standard used by industry for many years.  Equipped with your choice of 1, 2, 4, or 8 on-board relays, the ProXR Lite series Web Relay Controllers suit the needs of most of our customers.  Integrated Analog to Digital Converters may be used to manually control the relays, or they may be used to read external sensors.  Equipped with 8 or 10-Bit resolution, the ADC built into Web Relay Controllers add tremendous flexibility for various application requirements.Web Relays relays support DHCP or a Static IP address with a programmable port number, 2101 is used by default.  NCD Ethernet communications module will transmit the IP address of the device using periodic UDP broadcasts, which make it easy to locate the device on a network.
features
  • Updated Logos and Branding, Changed PCB Color to Black
  • Improved Relay Drive Circuit for Greater Noise Immunity
  • Improved Power Supply Circuit
    • Switcher Regulator for Lower Heat and Higher Power
    • Adds Compatibility with NCDD5500 Ethernet Module
    • Adds Compatibility with WiFi/Bluetooth Module
  • Use MQTT to Talk to this Device via WiFi Module
  • Use Integrated Web Page when using our New Ethernet or WiFi Module
  • Added Zip Tie Holes to Secure Communications Module
  • New Option for Pluggable Connectors on the Analog Inputs
  • Ferrite Beads for Improved Noise Separation of Logic and Drive Circuits
  • Updated LEDs to Address Supply Chain Limitations
  • 100% Identical Firmware with No Changes for Drop In Compatibility
  • 99% Identical Shape – Only Slight Changes to Connector Positioning
  • Built by our High-Speed Pick and Place Machine for High-Volume Runs
  • Legacy Status Product – Will Not Become Obsolete
  • Removed Temp. Sensor from Select Versions due to Errant Readings
how to use

Screenshot 2022-07-19 101535.png

Getting Started with NCD Web Relay Controller Boards

Start by downloading Base Station at https://ncd.io/start and Run the application.  A window will appear which listens for all NCD UDP broadcasts.  Plug in your Web Relay Board and wait for the Network window to populate with the IP address of the Web Relay Board. Enter the IP Address into a Web Browser or double click on the Web Relay Board in Base Station you should be brought to the Web Page for that board. From there you can configure the interface, control relays, or read inputs.

Base Station is a tool designed to teach you all the features built into your controller and provide you with example commands.  Base Station was written for Windows using Visual Studio (source code available on the download page linked above).  Base Station shows you all the commands you need for controlling relays and monitoring external sensors.

Base Station Software

Base Station Software was designed to help you learn the ProXR command set.  Explore ProXR features using our Graphical User Interface.  Watch data bytes flow to and from the board, so you easily understand the command execution process.  There is no faster or easier way to learn how to automate than Base Station, as it was designed to work  with our complete array of communication modules, including Wireless, Ethernet, USB, RS-232, and many more.  You only need a Windows 8 or 10 Computer to Run Base Station.  Base Station was written in Visual Studio, and we even provide the source code to help you on your way! Learn More about Base Station Software Here.

AD8 8-Channel 8/10-Bit Analog to Digital Converters

This controller is equipped with 8-Channels of 8/10-Bit Analog to Digital Converters, capable of reading analog voltages from 0 to 5 Volts DC.  The ADCs on this controller allow monitoring of external sensors or contact closure input detection.  Connect external temperature sensors, light sensors, current sensors, buttons, switches, or anything else that generates a 0-5VDC analog or contact closure output.  With 8-bit resolution, analog inputs will convert 0-5 Volt signals into a value from 0 to 255.  With 10-bit resolution, values of 0 to 1023 may be measured.  Input resolution is software selected.  Simply ask the controller for the analog value of each input, and the controller instantly responds.

Relay Activator and Analog Inputs

The Relay Activator control panel allows analog inputs to directly control relays.  Simply connect the analog inputs to buttons or switches and trigger basic relay on or off functions to take manual control of the on-board relays.  The Relay Activator control panel allows you to define 8 functions for each of the 8 inputs.  Functions include turning relays on or off, toggling the state of relays, momentarily flash a relay, momentarily toggle the flashing function of a relay, turn all relays on, turn all relays off, and push notification events.  When push notification events are configured, the controller generates a packet of data every time the inputs change state.

ProXR Lite Communication Options

We take communications seriously, as we believe in modular communications and firmware that properly supports scalability into future interface technologies.  ProXR controllers support API communications, which effectively wrap every command with a header, payload, and checksum to ensure reliability.  NCD API commands increase processing speed because no serial timeout is required prior to command processing.  NCD API commands increase reliability, as only a proper checksum will authenticate a command and allow it to process.  When we first implemented API, internet communications via a TCP/IP socket could be realized because the timing problems of internet communications were eliminated.  While API is optional, it is strongly advised.  Our Base Station software uses API communications, so it’s possible to control a ProXR controller over the internet after configuring port forwarding on your router.

ProXR series controllers are the world’s most adaptable controllers, capable of communicating with a wide variety of communication options.  Pick any of your favorite communication technologies: Bluetooth, USB, WiFi, Ethernet, Key Fob, RS-485 or RS-232. ProXR easily adapts to the communication technologies you need most.  We are committed to modular communications, so your ProXR series controllers can easily be retrofitted for other applications as your needs change.  ProXR controllers are never obsolete, as we are actively releasing new communication technologies that greatly enhance the connectivity of our ProXR series controllers.

documents
Schematics
AD8 Connections
20-30-Amp Relay Connections
Others
AD8 8-Channel Analog to Digital Converter Quick Start Guide Documentation
EEPROM Memory Map Quick Start Guide
Official Repository

COMMENTS

Please Login to comment
  Subscribe  